HeatLoss Pro

Room-by-room heat loss and heat pump sizing in about 5 minutes.

Trace the walls over a floor plan and HeatLoss Pro works out each room's heat loss as you draw, in 2D and 3D. It sizes the heat pump from the unit's own datasheet, checks radiators, underfloor heating and fan coils at low flow temperatures, and sizes the pipes. Drawing is free, and so is the whole house's heating and cooling power each time you press Calculate; the room-by-room calculation and its report cost €1.

  • About 5 minutes per house
  • EN 12831 room-by-room method
  • Whole house free, room by room €1
  • English, Nederlands, Français, Deutsch
HeatLoss Pro designer showing a two-floor demo house in 3D with the heat loss of every wall and room
5 minutes
From floor plan to heat pump size
Room by room
Walls, windows, floor, roof and air
Low-temperature
Radiators and UFH at 35–45 °C water
Free
Whole-house heating and cooling power

How it works

From floor plan to heat pump size

No spreadsheets and no CAD package. Draw the house once and every figure follows it.

  1. 01 · Trace

    Trace the floor plan

    Paste a plan with Ctrl+V, upload a PDF, a photo of a drawing or a map screenshot, set the scale with the two-point ruler and draw the walls over it. Walls snap to the grid and to 45° and 90°.

    • Interior and exterior walls detected automatically
    • Several floors, pitched roofs and unheated rooms
    • Presets for walls, glazing and insulation, or your own U-values
  2. 02 · Calculate

    Press Calculate

    Click a wall and the panel estimates its loss while you draw. Press Calculate and the whole house's heating and cooling power comes back free; each room's own heat loss comes with a single calculation.

    • Fabric loss from U-values and areas
    • Ventilation and infiltration (air changes per hour)
    • Turn the house in 3D to check every surface
  3. 03 · Size

    Size the system and get the report

    Pick a heat pump from its datasheet figures, add radiators, underfloor heating or fan coils and the pipes between them, then calculate. The report lists every room, emitter and pipe.

    • Emitter output against each room's loss
    • Pipe sizes, flow, pump head and balancing
    • A client-ready report you can share

Walkthrough

The demo, step by step

These screens come from the demo that plays on your first visit: a small house drawn, calculated and heated in about four minutes.

The Line tool drawing the outside walls of a house, with the wall lengths and the next line's height, function and insulation

Step 1

Draw the outside walls

Pick the Line tool (press L) and click each corner of the house, or type a length and press Enter. Over a pasted plan or photo, set the scale first and trace it.

  • Walls snap to the grid and to 45° and 90°
  • Height, function and insulation in the bar above the canvas
Four outside walls selected together and set to solid stone in the wall bar

Step 2

Set the insulation

Pick all the outer walls at once from the Select menu and change them together: here, old solid stone with no insulation. The panel estimates their loss straight away.

  • Presets for walls, glazing, floors and roofs
  • Or build a wall from its layers for its own U-value
The house with windows along its outside walls and inside walls splitting it into five rooms

Step 3

Add windows and inside walls

Draw a line along an outside wall and it becomes a window. Draw across the house and it becomes an indoor partition: each closed space turns into a room by itself.

  • Window sizes and glazing per window
  • Doorways and openings between rooms
The rooms named Living, Master bedroom, Bedroom 2, Corridor and Bathroom, with the bathroom selected

Step 4

Name the rooms and set their temperatures

Click a room and type its name. A bathroom is kept warmer: set its temperature in the panel, or pick its room type and the country's rules set it.

  • Ceiling height and roof per room
  • Unheated rooms, and rooms heated through open doorways
The free basic result: 7.6 kW of heating and 6.0 kW of cooling for the whole house, above the single calculation

Step 5

Press Calculate: the whole house, free

The heating and cooling power the whole house needs at the design temperatures, with no account and no card. Enough to check that a quoted heat pump is about the right size.

  • Free once every 5 minutes
  • A single calculation or Pro to go further
Each room's heat loss in kW and every wall's and window's loss in watts after the calculation

Step 6

Room by room for €1

A single calculation gives each room's heat loss and the loss through every wall and window, with 20 changes included to correct the drawing and calculate again.

  • The room-by-room method of EN 12831
  • The upgrades that would save the most
Radiators in each room, underfloor heating in the bathroom, a manifold with a mixing valve and the flow and return pipes

Step 7

Add the heating system

Switch to Heating. Place a radiator in each room, tick underfloor heating in the bathroom, find your heat pump by brand or model and draw the pipes from the manifold. Calculate again and every room shows how much of its loss its emitters cover.

  • A mixing valve keeps underfloor loops cooler
  • Pipe sizes, flow and pump head checked
The report: design heat loss 7.6 kW, recommended heat pump 8.0 kW, and the heating and cooling demand against the outdoor temperature

Step 8

Share the report

The report sums up the house, the recommended heat pump and every room, with the heating and cooling demand against the outdoor temperature. Print it or save it as a PDF for your client.

  • Room temperatures simulated at every outdoor temperature
  • Your own logo on the report with Pro

Inside the designer

One drawing, three ways to read it

These screens show the demo house that opens on your first visit.

Demo house in 3D with the heat loss of each wall and room
Floor plan

Heat loss in 3D

Turn the house around, click a wall, window or opening to edit it, and drag the handles to change heights. The panel on the right sums up the house.

  • Loss per surface and per room
  • Heat pump output against demand at the design temperature

Features

Built for heat pumps at low flow temperatures

A heat pump runs best with cool water, so the tool checks whether the emitters still keep each room warm at 35–45 °C.

Room-by-room heat loss

Follows the room-by-room method of EN 12831: each surface times its U-value and the temperature difference, plus the air that leaks or is ventilated out.

Heat pump sizing from datasheets

Heating is rated at +7 °C and cooling at +35 °C. The output at your design temperature comes from the unit's own datasheet point, never a generic curve.

Radiators at low temperature

Radiator output is derated for 45/35 °C water (EN 442). Cast-iron column radiators can be entered by their size and sections.

Underfloor heating and fan coils

UFH output from water temperature, pipe coverage and floor finish (tiles, wood or carpet). Fan coils for winter heating and summer cooling.

Pipes, pumps and balancing

Pipe sizes by velocity and friction, bend losses, circuit pressure against the pump head, and the lockshield setting each radiator needs.

Summer cooling

A temperature sweep from −15 °C to +38 °C shows heat loss, heat pump capacity and cooling load on one curve.

Quick estimate from your bill

No time to draw? Estimate the heat loss in 30 seconds from yearly gas (m³) or heating oil (litres), or from the boiler's rating plate.

Save and share

Sign in with a magic link sent by email, no password. Share a design with a link; without signing in, drawings stay in your browser.

Four languages

The designer and its guides are in English, Dutch, French and German, and numbers are shown in your own format.

Pricing

The whole house free. Room by room from €1.

Draw, trace and press Calculate without paying: the heating and cooling power of the whole house is free. You pay when you want each room, the radiators and the report.

  • No account to start. Open the designer and draw straight away. The free result needs no account and no card.
  • Free basic result. The whole house's heating and cooling power at the design temperatures, once every 5 minutes, for as long as we can keep offering it.
  • Changes included. A single calculation includes later changes to the same design, so a correction does not cost another euro.
  • No lock-in. Subscriptions can be cancelled at any time. A first-year discount on the yearly plan, when offered, applies to the first year only.
  • Basic result Draw and trace, then the whole house's heating and cooling power at every Calculate
    Free
  • Monthly subscription Unlimited calculations and reports, cancel any time
    €29.99
  • Yearly subscription The same, paid once a year, with a first-year discount when offered
    €359.88

Comparison

HeatLoss Pro vs spreadsheets and desktop CAD

Where each approach fits, including where the heavier tools are the better pick.

HeatLoss Pro vs spreadsheets and desktop CAD
Compared onHeatLoss ProVisual, in the browserSpreadsheetsMCS-style workbooksDesktop CADEngineering suites
Time per houseTypical survey to resultAbout 5 minutesAbout 60–90 minutesFast once trained, slow to learn
InputHow the house gets inTrace over a pasted plan or photoType every area by handFull building model
Emitters and pipesRadiators, UFH, hydraulicsRadiators, UFH, fan coils, pipes and balancingUsually radiators onlyComplete hydraulic design
CostWhat you commit toWhole house free; room by room €1, or €29.99/month or €359.88/yearOften freeAnnual licences, often thousands of euros per seat
Best forWho it suitsInstallers, surveyors and homeownersOne-off checks by someone who knows the methodLarge projects and engineering offices

For a feature-by-feature comparison with Heatpunk and named CAD packages, see the comparison page on heatlosspro.cloud. Other products' prices change; check their sites before you buy.

FAQ

Questions about HeatLoss Pro

How long does a heat loss calculation take?

About 5 minutes for a typical house once you have a floor plan: trace the walls, set the insulation and windows, and the room-by-room heat loss appears as you draw.

Which method does HeatLoss Pro use?

The room-by-room method of EN 12831: each wall, window, floor and roof times its U-value and the difference between room and design outdoor temperature, plus the ventilation loss. The heat pump is then sized on the whole house at that design temperature.

How much does it cost?

Drawing is free, and so is the basic result: the heating and cooling power of the whole house, each time you press Calculate (once every 5 minutes). Each room's heat loss, the radiator and underfloor heating check and the report cost €1.00 per design. A subscription at €29.99 a month or €359.88 a year gives unlimited calculations and can be cancelled at any time.

What do I get for free?

Draw the house, trace a plan and press Calculate: the free basic result gives the heating and cooling power the whole house needs at the design temperatures, enough to check whether a quoted heat pump is about the right size. No account and no card. It does not include each room's figures, the emitter check or the report.

Do I need to install anything or create an account?

No. HeatLoss Pro runs in the browser. You can start drawing straight away; signing in with an email magic link keeps your drawings on every device.

Can it size radiators and underfloor heating for a heat pump?

Yes. Radiator output is derated for low flow temperatures (EN 442), underfloor heating output follows water temperature, coverage and floor finish, and each room shows whether its emitters cover its loss.

Is it tied to a heat pump brand?

No. HeatLoss Pro is independent. You enter any heat pump from its own datasheet figures.

Can I rely on the result to buy a heat pump?

The result is only as good as the drawing and the values in it. It is an estimate, not a survey: have an installer or engineer check anything you intend to buy or build from.

Work out your heat loss in 5 minutes

Open the designer, watch the demo or paste your own floor plan. The whole house's result is free.